*Genotronics is committed for customer satisfaction and quality. our organization is engaged in Trading, Importing , supplying and service provider we are offering a wide range of Medical Equipment. These equipment are manufactured at hi-tech manufacturing unit under the observations of Expert professionals. Our range is durable, efficient, accurate in results and portable as well. Further these Medical Equipment can be availed from us at reasonable prices.
Neonates are a very special group whose BP, ECG and SpO2 are of great differences from the adult's. Measurement of ECG, HR and RESP is usually inaccurate when using traditional monitors. Also inexperienced nurses always accidentally adopt adult mode to measure neonate's blood pressure, which will easily bruise neonate's arm. Based on neonate's needs, Comen creates the world's first specialized neonatal monitor,which is safer, more accurate, more stable and more convenient.
Adap-DSP (Adaptable digital signal processor)
The exclusive apnea self-saving function can stop sleep apnea and relieve neonate of the danger so as to fully care for them.
Through oxygen sensor monitoring the oxygen concentration, medical staff can learn at any time the change of oxygen concentration inside the incubator.
Through oxygen sensor monitoring the oxygen concentration, medical staff can learn at any time the change of oxygen concentration inside the incubator.
160mmHg cuff pressure will easily bruise neonate's arm when adult mode is accidentally used to measure neonate's BP. The one and only measurement mode in C60 can avoid such negligence. Regarding neonate's low BP and weak perfusion, use Adap-DSP® to make BP measurement more accurate.
Touch screen, support handwriting input.
Item | Adult (general) |
Neonate (general) |
Why to choose specialized C60 | |
---|---|---|---|---|
BP | SBP DBP Cuff pressure |
90~100mmHg 60~90mmHg 1st inflation pressure 160mmHg |
70~82mmHg 30~38mmHg 1st inflation pressure 100mmhg |
Use adaptable digital signal processing, creatively use 0~150mmHg low BP Adap-Dsp algorithm to ensure accuracy. If use adult mode to measure neonate, 160mmHg cuff pressure might hurt its arm, one neonatal measurement mode |
ECG | HR RESP ECG signal |
60~100bpm 16~18bpm Strong, low frequency |
120~160bpm 40~45bpm Weak, high frequency |
Regarding neonate's high HR/RESP and weak ECG signal, Comen specially develops ExNeo®ECG Technology, only for neonates |
SpO2 | Peripheral arterial perfusion index | 3%~5% Remain static |
0.05%~2% Active, cannot keep still |
Regarding neonate's high HR/RESP and weak ECG signal, Comen specially develops ExNeo®ECG Technology, only for neonates. |
Apnea self-saving | No | Yes | Detect apnea symptom, activate alarm and self-save the baby before staffs get there | |
O2 concentration Monitoring | No | Yes | Real time monitoring of oxygen concentration inside the incubator, which is very important | |
Accessory | 1cuff, 1 SpO2 detector | 4 cuffs, 2 SpO2 detectors | Neonate's are different from adult's. | |
User | Professionals from different apartments | Professionals from Neonatology | Love and only love C60's focus |